258
10 OBJECT DICTIONARY
10.1 Object dictionary list
2B2D
0
Unit power consumption
The unit power consumption is
returned.
I16
ro
Possible
8000h to
7FFFh
W
2B2E
0
Unit total power consumption
The unit total power consumption
is returned.
I32
ro
Possible
80000000h to
7FFFFFFFh
Wh
2B2F
0
Current position
The current position is returned.
In the indexer method, the value
is fixed to 0.
I32
ro
Possible
80000000h to
7FFFFFFFh
pos units
2B30
0
Command position
The command position is
returned. In the indexer method,
the value is fixed to 0.
I32
ro
Possible
80000000h to
7FFFFFFFh
pos units
2B31
0
Command remaining distance
The command remaining
distance is returned.
I32
ro
Possible
80000000h to
7FFFFFFFh
pos units
2B32
0
Point table No./Station position
No.
Point table No. or station position
No. is returned.
I16
ro
Possible
0000h
to 00FFh
2B81
0
Alarm Monitor 1 Cumulative
feedback pulses
The cumulative feedback pulses
at alarm occurrence are returned.
I32
ro
Possible
80000000h to
7FFFFFFFh
pulse
2B82
0
Alarm Monitor 2 Servo motor
speed
The servo motor speed at alarm
occurrence is returned.
I32
ro
Possible
80000000h to
7FFFFFFFh
r/min
mm/s
2B83
0
Alarm Monitor 3 Droop pulses
The droop pulses at alarm
occurrence are returned.
I32
ro
Possible
80000000h to
7FFFFFFFh
pulse
2B84
0
Alarm Monitor 4 Cumulative
command pulses
The cumulative command pulses
(encoder unit) at alarm
occurrence are returned.
I32
ro
Possible
80000000h to
7FFFFFFFh
pulse
2B85
0
Alarm Monitor 5 Command pulse
frequency
The command pulse frequency at
alarm occurrence is returned.
I32
ro
Possible
80000000h to
7FFFFFFFh
kpulse/s
2B88
0
Alarm Monitor 8 Regenerative
load ratio
The regenerative load ratio at
alarm occurrence is returned.
U16
ro
Possible
0000h to
FFFFh
%
2B89
0
Alarm Monitor 9 Effective load
ratio
The effective load ratio at alarm
occurrence is returned.
U16
ro
Possible
0000h to
FFFFh
%
2B8A
0
Alarm Monitor 10 Peak load ratio
The peak load ratio at alarm
occurrence is returned.
U16
ro
Possible
0000h to
FFFFh
%
2B8B
0
Alarm Monitor 11 Instantaneous
torque
The instantaneous torque at
alarm occurrence is returned.
I16
ro
Possible
8000h to
7FFFh
%
2B8C
0
Alarm Monitor 12 Within one-
revolution position
The position within one-
revolution at alarm occurrence is
returned.
I32
ro
Possible
80000000h to
7FFFFFFFh
pulse
2B8D
0
Alarm Monitor 13 ABS counter
The ABS counter at alarm
occurrence is returned.
I32
ro
Possible
80000000h to
7FFFFFFFh
rev
Index
Sub
Index
Name and function
Data
Type
Access Variable
mapping
Default
Range
Units
EEP-
ROM
Parameter