266
10 OBJECT DICTIONARY
10.1 Object dictionary list
2D50
0
One-touch tuning mode
Setting "1" to "3" starts one-touch
tuning. After one-touch tuning is
completed, the setting value
automatically changes to "0".
1: Basic setting
2: High setting
3: Low setting
U8
rw
Impossible
0
00h to 03h
2D51
0
One-touch tuning status
The one-touch tuning progress is
returned.
I8
ro
Impossible
0
00h to 64h
%
2D52
0
One-touch tuning Stop
Writing "1EA5h" can stop one-
touch tuning. Any value other
than "1EA5h" is invalid.
U16
wo
Impossible
0000h/1EA5h
2D53
0
One-touch tuning Clear
The parameter changed in one-
touch tuning can be returned to
the value before the change. The
description of the setting values
is as follows.
0000: Restores the default value
0001: Restores the value before
one-touch tuning
U16
wo
Impossible
0000h to
0001h
2D54
0
One-touch tuning Error Code
An error code of the one-touch
tuning is returned. The
description of the error codes is
as follows.
0000: Finished normally
C000: Tuning canceled
C001: Overshoot exceeded
C002: Servo-off during tuning
C003: Control mode error
C004: Time-out
C005: Load to motor inertia ratio
misestimated
C00F: One-touch tuning disabled
U16
ro
Impossible
0
0000h to
C00Fh
2D60
0
Target point table
In the point table mode (pt)
Specify a point table No.
0: Not operate
1 to 255: Execute the specified
point table
-1: High-speed home position
return
In the indexer mode (idx)
Specify the next station No.
0 to 254: Positioning operation to
specified stations
I16
rw
Possible
0
pt:
FFFFh to
00FFh
idx:
0000h to
00FEh
2D68
0
Point demand value
The currently specified point
table error No. can be read. The
returned values vary depending
on the control mode.
I16
ro
Possible
pt:
FFFFh to
00FFh
idx:
0000h to
00FEh
2D69
0
Point actual value
In the point table mode (pt), the
completed point table No. is
returned.
After homing completed, "0" is
set.
In the indexer mode (idx), the
completed station No. is
returned. The previous value is
held until completion.
I16
ro
Possible
pt:
FFFFh to
00FFh
idx:
0000h to
00FEh
Index
Sub
Index
Name and function
Data
Type
Access Variable
mapping
Default
Range
Units
EEP-
ROM
Parameter