146
6 SERVO MOTOR DRIVING
6.3 Indexer mode (idx)
Function and related objects
The following shows the functions and related objects of the indexer mode (idx).
Related object
Index
Sub
Name
Data Type
Access
Default
Description
607Fh
Max profile velocity
U32
rw
2000000
Maximum speed
Unit: Vel unit (0.01 r/min)
6080h
Max motor speed
U32
rw
Servo motor maximum speed
Unit: r/min
6081h
Profile velocity
U32
rw
10000
Speed after acceleration completed
Unit: Vel unit (0.01 r/min)
6083h
Profile acceleration
U32
rw
0
Acceleration at start of movement to target
position
Unit: ms
6084h
Profile deceleration
U32
rw
0
Deceleration at arrival at target position
Unit: ms
6085h
Quick stop
deceleration
U32
rw
100
Deceleration time constant for Quick stop
Unit: ms
605Ah
Quick stop option
code
I16
rw
2
Operation setting for Quick stop
6063h
Position actual
internal value
I32
ro
Current position (Enc inc)
6064h
Position actual
value
I32
ro
Current position (Pos units)
Fixed to 0
606Ch
Velocity actual
value
I32
ro
Current speed
Unit: Vel unit (0.01 r/min)
6077h
Torque actual value
I32
ro
Current torque
Unit: 0.1% (rated torque of 100%)
6092h
0
Feed constant
U8
ro
2
Travel distance per revolution of an output shaft
1
Feed
U32
rw
Travel distance setting
2
Shaft revolutions
Number of servo motor shaft revolutions
Position
trajectry
generator
+
×
×
×
×
-
Control
effort
(60FAh)
Position actual internal value (6063h)
×
×
Torque
limit
function
Velocity
limit
function
Acceleration
limit
function
Position
control
Velocity
control
Torque
control
Encoder
Motor
Profile acceleration (6083h)
Profile deceleration (6084h)
Quick stop deceleration (6085h)
Quick stop option code (605Ah)
Target point table (2D60h)
Profile velocity (6081h)
Max motor speed (6080h)
[Pr. PC77]
Gear ratio (6091h)
Polarity (607Eh)
Following error actual value (60F4h)
Velocity actual value (606Ch)
Torque actual value (6077h)
×
Max profile velocity (607Fh)
Torque limit value (60E0h, 60E1h)
×
Point actual value (2D69h)
Point demand value (2D68h)
M code actual value (2D6Ah) (Fixed to 0)
Position actual value (6064h) (Fixed to 0)