248
9 MANUFACTURER FUNCTIONS
9.6 Override
• When [Pr. PT42] is set to 50 and [Pr. PT43] is set to 5 in the rotation direction specifying indexer
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
0 r/min
Control DI8 bit 3 to bit 6
1
3
1
3
1
3
1
Status DO5 bit 6
(S_MEND)
Point actual value
Controlword bit 4
(New set-point)
Controlword bit 5
(Direction)
Target point table
Power supply
ALM (Malfunction)
All turned off
All turned off
All turned off
All turned off
Digital override 100 %
Digital override 85 %
Station position No. 1
Station
position No. 1
Station
position No. 3
Forward
rotation
Servo motor speed
Station position
No. 3
Reverse
rotation
Digital override 50 %
Within 3.5 ms
Digital
override 85 %
Digital override 100 %
Digital override 50 %
Digital override 115 %
(S_OV0 to S_OV3)
Digital override 115 %