9 MANUFACTURER FUNCTIONS
9.5 Simple cam function
243
9
Cam axis feed current value restoration
• When the restored cam axis feed current value differs from the feed current value at cam control switching,
the cam axis feed current value moves to the value restored just after cam control switching.
• If the difference between the restored cam axis feed current value and the feed current value is larger than
the value set in [Pr. PA10 In-position range], [AL. F6.2 Cam axis feed current value restoration failed] will
occur and the control cannot be switched to the cam control. Note that increasing the value of the in-position
range may lead to a rapid cam switching.
When the cam axis position restoration target is set to "Cam axis feed current value restoration", and then bit 5 of Control DI2
(2D02h) turns on, the control is switched to the cam control, restoring the "Cam axis feed current value" based on the "Cam
axis current value per cycle" and the "Cam standard position".
Set the "Cam axis current value per cycle" and "Cam standard position" used for the restoration with cam control data.
Cam axis one cycle
current value
Cam axis feed current value
Cam standard position