4 STARTUP
4.3 Switch setting and display of the servo amplifier
Scrolling display
Axis number will be displayed in hexadecimal.
Normal display
When there is no alarm, the identification number (2 digits) is displayed.
Alarm display
When an alarm occurs, the alarm number (two digits) and the alarm detail (one digit) are displayed following the status
display.
For example, the following shows when [AL. 32 Overcurrent] is occurring.
If an alarm occurs during initial communication through a network, the status, the alarm number (two digits) and alarm detail
(one digit), and the network initial communication status are displayed, in that order. For example, the following shows when
[AL. 16.1 Encoder initial communication - Receive data error 1] is occurring.
Status
(1 digit)
Identification
No. (2 digits)
"b": Indicates ready-off and servo-off status.
"C": Indicates ready-on and servo-off status.
"d": Indicates ready-on and servo-on status.
After 0.8 s
After 0.8 s
Status
Alarm No.
Blank
After 0.2 s
Alarm No.
(2 digits)
Alarm detail
(1 digit)
Status
(1 digit)
Identification
No. (2 digits)
"n": Indicates that an alarm is occurring.
After 0.8 s
After 0.8 s
After 0.2 s
After 1.6 s
Status
Alarm No.
Blank
Network initial
communication
status
Blank
After 0.2 s
Alarm
No. (2 digits)
Alarm
detail
(1 digit)
Status
(1 digit)
Identification
No. (2 digits)
"n": Indicates that an alarm is occurring.