4 STARTUP
4.5 Test operation mode
49
4
■
Positioning operation
Positioning operation can be performed without a master station (controller). Use this operation with the forced stop reset.
This operation may be used independently of whether servo-on or servo-off and whether a master station (controller) is
connected or not.
Perform on the positioning operation screen of MR Configurator2.
• Operation pattern
• Operation method
■
Program operation
Positioning operation can be performed with two or more operation patterns combined, without using a master station
(controller). Use this operation with the forced stop reset. This operation may be used independently of whether servo-on or
servo-off and whether a master station (controller) is connected or not.
Perform on the program operation screen of MR Configurator2. For full information, refer to the MR Configurator2 Installation
Guide.
■
Output signal (DO) forced output
Output signals can be switched on/off forcibly independently of the servo status. Use this function for checking output signal
wiring, etc. Perform on the DO forced output screen of MR Configurator2.
Item
Initial value
Setting range
Travel distance [pulse]
4000
0 to 99999999
Servo motor speed [r/min]
200
0 to Maximum speed
Accel./decel. time constant [ms]
1000
0 to 50000
Repeat pattern
Forward rotation (CCW)
Reverse rotation (CW)
Forward rotation (CCW)
Reverse rotation (CW)
Forward rotation (CCW)
Forward rotation (CCW)
Reverse rotation (CW)
Forward rotation (CCW)
Reverse rotation (CW)
Reverse rotation (CW)
Dwell time [s]
2.0
0.1 to 50.0
Number of repeats [time]
1
1 to 9999
Operation
Screen operation
Forward rotation start
Click "Forward CCW".
Reverse rotation start
Click "Reverse CW".
Temporary stop
Click "Pause".
Stop
Click "Stop".
Forced stop
Click "Forced Stop".
Operation
Screen operation
Start
Click "Operation start".
Temporary stop
Click "Pause".
Stop
Click "Stop".
Forced stop
Click "Forced Stop".