238
9 MANUFACTURER FUNCTIONS
9.5 Simple cam function
■
Cam pattern of to-and-fro control
• Searching from "Cam axis one cycle current value = 0" (Cam data start position = 0)
• Searching from a value in the middle of the cam axis one cycle current value (Cam data start position = 0)
• Searching from a value in the middle of the cam axis one cycle current value (Cam data start position
0)
Cam axis one cycle
current value
Search from "Cam axis one cycle current value = 0".
Cam axis feed current value
(Feed current value)
The cam axis one cycle current value is restored with the first feed
current value that matched.
(The cam axis one cycle current value is not restored with the second and
subsequent feed current values that matched.)
Cam standard position
Cam axis one cycle current value (initial setting value)
Cam axis one cycle
current value
Search from a value in the middle of the cam axis one cycle current value.
(Preceding feed current values are searched later.)
Search from a value in the middle, and the cam axis one cycle
current value is restored with the first feed current value that matched.
(The cam axis one cycle current value is restored with the second feed
current value that matched.)
Cam axis feed current value
(Feed current value)
Cam standard position
Cam axis one cycle current value (initial setting value)
Cam axis one cycle
current value
Search from a value in the middle of the cam axis
one cycle current value.
Cam axis feed current value
(Feed current value)
Cam data start
position
Cam standard position
Search from a value in the middle, and the cam axis
one cycle current value is restored with the first feed
current value that matched.