112
6 SERVO MOTOR DRIVING
6.2 Point table mode (pt)
Setting method of point tables using objects
To change the point table of the servo amplifier on the master station (controller), write values to the following objects in the
SDO communication. However, once the power supply is shut off, the changed setting is not held at the next startup. To hold
the changed setting even after the power supply is shut-off, save the point table setting value to EEP-ROM using Store
Parameters (1010h).
Index
Sub Index
Name
Data Type
Access
Default
Description
2801h
0
Point table001
U8
ro
7
Number of entries
1
Point data
I32
rw
Set the position data of the point table No.
1.
2
Speed
U32
rw
Set the servo motor speed of the point
table No. 1.
3
Acceleration
U16
rw
Set the acceleration time constant of the
point table No. 1.
4
Deceleration
U16
rw
Set the deceleration time constant of the
point table No. 1.
5
Dwell
U16
rw
Set the dwell of the point table No. 1.
6
Auxiliary
U8
rw
Set the auxiliary function of the point table
No. 1.
28FFh
0
Point table255
U8
ro
7
Number of entries
1
Point data
I32
rw
Set the position data of the point table No.
255.
2
Speed
U32
rw
Set the servo motor speed of the point
table No. 255.
3
Acceleration
U16
rw
Set the acceleration time constant of the
point table No. 255.
4
Deceleration
U16
rw
Set the deceleration time constant of the
point table No. 255.
5
Dwell
U16
rw
Set the dwell of the point table No. 255.
6
Auxiliary
U8
rw
Set the auxiliary function of the point table
No. 255.