42
4 STARTUP
4.3 Switch setting and display of the servo amplifier
4.3
Switch setting and display of the servo amplifier
Switching to CC-Link IE Field Network Basic communication or test operation mode, and setting identification number are
enabled with switches on the servo amplifier.
On the servo amplifier display (three-digit, seven-segment LED), check the identification number, and diagnose a malfunction
at occurrence of an alarm. The Ethernet communication status can be checked on the LED of the CN1A connector.
Switches
• Turning "ON (up)" all the slide switches (SW1) causes the mode to change to an operation mode for
manufacturer setting and "off" to appear on the display. This mode is not available. Set the slide switches
(SW1) correctly according to this section.
• Cycling the main circuit power supply and control circuit power supply enables the setting of each switch.
The following diagram explains the slide switches and rotary switches.
WARNING
• When switching the rotary switches (SW2/SW3) or slide switches (SW1), use an insulated screw driver. Do not use a metal screw driver. Touching patterns
on electronic boards, lead of electronic parts, etc. may cause an electric shock.
1
ON
2
SW1-2
SW1-1
1
ON
2
3-digit, 7-segment LED
Slide switches (SW1)
Rotary switch (upper) (SW2)
Rotary switch (lower) (SW3)