6-32
9. WHEN FUEL GAUGE DOES NOT OPERATE (HCESPN 301, FMI 3 or 4)
余
Before disconnecting the connector, always turn the starting switch OFF.
余
Before carrying out below procedure, check all the related connectors are properly inserted.
余
After checking, insert the disconnected connectors again immediately unless otherwise specified.
CN-51
MCU
5
CN-52
26
CD-2
2
1
FUEL LEVEL SENDER
Cause
Remedy
Defective MCU or
cluster
Disconnection in
wiring harness or
poor contact
between fuel
sender-MCU
Defective fuel
sender
Replace
Repair or replace
Replace
YES
YES
Starting switch : OFF
Spec : 50~600
凂
See table
Check resistance
between fuel
sender (1) and
(2)
Check resistance
between CN-51
(5) and CN-52
(26)
Starting switch : OFF
Disconnect CN-51
Spec : 50~600
凂
NO
NO
300L6ES10
Check Table
Range
Resistance (
凂
)
Range
Resistance (
凂
)
Full
50
5/12
400
11/12
100
4/12
450
10/12
150
3/12
500
9/12
200
2/12
550
8/12
250
1/12
600
7/12
300
Empty warning
700
6/12
350
-
-
(SERIAL NO. : -#0610)
Summary of Contents for HX140L
Page 12: ...SECTION 1 GENERAL SECTION 1 GENERAL Group 1 Safety Hints 1 1 Group 2 Specifications 1 10...
Page 209: ...4 5 MEMORANDUM...
Page 694: ...8 68 125LCR8TM30 Turn casing 1 upside down and remove oil seal 3 using jig 29...
Page 734: ...8 108 Assemble plug 2 Plug NPT1 16 11 EA 17 21078TM68 21078TM69 21078TM70 21078TM71...
Page 756: ...8 130 Remove lock nut 22 and then boot 23 14 36078RL14 2507ARL10...