6-39-5
5. WHEN AIR CLEANER WARNING LAMP LIGHTS UP (engine is started)
余
Before disconnecting the connector, always turn the starting switch OFF.
余
Before carrying out below procedure, check all the related connectors are properly inserted.
余
After checking, insert the disconnected connectors again immediately unless otherwise specified.
Cause
Remedy
Clogged air filter or
defective switch
Short circuit in
wiring harness
between CD-10A-
CN-54 (13)
Defective united
MCU
Check filter or
replace switch
Repair or replace
(After clean)
Replace
25
AIR CLEANER CLOGGING SW
GND (FOR SENSOR 5V)
CN-51
13
CN-54
AIR CLEANER SWITCH
Pa
UNITED MCU
CD-10A
Starting switch : ON
Engine : Start
Does display go
off when
disconnect
CD-10A
Check resistance
between CN-54
(13) and chassis
NO
YES
NO
YES
Starting switch : OFF
Disconnect CN-54
YES
NO
MAX 1
凂
MIN 1M
凂#
Check resistance
140L6ES106
(SERIAL NO. : #0611-)