5-46
J1939 Code
Description
Effect and Action
3361-5
Aftertreatment #1 DEF/AdBlue®
Dosing Unit : Current Below Normal
The ECM detects the following conditions:
A low current condition in the output from the DCU to the
solenoid in the DEF.
There are no active 168 diagnostic codes.
The warning lamp will come on. The diagnostic code will be
logged.
Solenoid Valve - Test (Solenoid Valves that Connect to the
Dosing control Unit (DUC))
3361-6
Aftertreatment #1 DEF/AdBlue®
Dosing Unit : Current Above Normal
The ECM detects the following conditions:
A high current condition in the output from the DCU to the
solenoid in the DEF.
There are no active 168 diagnostic codes.
The warning lamp will come on. The diagnostic code will be
logged.
Solenoid Valve - Test (Solenoid Valves that Connect to the
Dosing control Unit (DUC))
3361-7
Aftertreatment #1 DEF/AdBlue®
Dosing Unit : Not Responding
Property
DEF/AdBlue® Module Does Not Respond
3363-5
Aftertreatment #1 DEF/AdBlue® Tank
Heater : Current Below Normal
The ECM detects the following conditions:
A low current condition in the output from the DCU to the
solenoid in the DEF.
There are no active 168 diagnostic codes.
The warning lamp will come on. The diagnostic code will be
logged.
Solenoid Valve - Test (Solenoid Valves that Connect to the
Dosing control Unit (DUC))
3363-6
Aftertreatment #1 DEF/AdBlue® Tank
Heater : Current Above Normal
The ECM detects the following conditions:
A high current condition in the output from the DCU to the
solenoid in the DEF.
There are no active 168 diagnostic codes.
The warning lamp will come on. The diagnostic code will be
logged.
Solenoid Valve - Test (Solenoid Valves that Connect to the
Dosing control Unit (DUC))
3509-3
Sensor Supply Voltage 1 : Voltage
Above Normal
The Electronic Control Module (ECM) detects the following
conditions:
The 5 VDC supply for the sensors is greater than 5.16 VDC
for more than one second.
The ECM has been powered for at least 3 seconds.
Diagnostic code 168-4 is not active.
The warning lamp will come on. The ECM sets all the
sensors on the 5 VDC circuit to the default values.
The engine will be derated.
5 V Sensor Supply Circuit - Test
侍#
Some fault codes are not applied to this machine.
Summary of Contents for HX140L
Page 12: ...SECTION 1 GENERAL SECTION 1 GENERAL Group 1 Safety Hints 1 1 Group 2 Specifications 1 10...
Page 209: ...4 5 MEMORANDUM...
Page 694: ...8 68 125LCR8TM30 Turn casing 1 upside down and remove oil seal 3 using jig 29...
Page 734: ...8 108 Assemble plug 2 Plug NPT1 16 11 EA 17 21078TM68 21078TM69 21078TM70 21078TM71...
Page 756: ...8 130 Remove lock nut 22 and then boot 23 14 36078RL14 2507ARL10...