5-25
5-21-4
DTC
Diagnostic Criteria
Application
HCESPN FMI
G
C
W
164
4
(Detection)
(When Working Cutoff Relay is Off)
10 seconds continuous, Working Cutoff Relay drive unit Measurement
Voltage
£
3.0V
(Cancellation)
(When Working Cutoff Relay is Off)
3 seconds continuous, Working Cutoff Relay drive unit Measurement
Voltage > 3.0V
侑
6
(Detection)
(When Working Cutoff Relay is On)
10 seconds continuous, Working Cutoff Relay drive current > 6.5 A
(Cancellation)
(When Working Cutoff Relay is On)
3 seconds continuous, Working Cutoff Relay drive current
£
6.5 A
侑
(Results / Symptoms)
1. Control Function – (Wheel Excavator) In driving mode, attachment hydraulic pilot pressure cut off
failure
(Checking list)
1. CR-47 (#85) – CN-54 (#9) Checking Open/Short
2. CR-47 (#30, #86) – Fuse box (#28) Checking Open/Short
166
4
(Detection)
(When Power Max Solenoid is Off)
10 seconds continuous, Power Max Solenoid drive unit Measurement
Voltage
£
3.0V
(Cancellation)
(When Power Max Solenoid is Off)
3 seconds continuous, Power Max Solenoid drive unit
Measurement Voltage > 3.0V
侑
6
(Detection)
(When Power Max Solenoid is On)
5 seconds continuous, Power Max Solenoid drive current > 4.5 A
(Cancellation)
(When Power Max Solenoid is On)
3 seconds continuous, Power Max Solenoid drive current
£
4.5 A
侑
(Results / Symptoms)
1. Control Function – Voltage increase operation failure
(Checking list)
1. CN-88 (#1) – CN-52 (#2) Checking Open/Short
2. CN-88 (#2) – Fuse box (#30) Checking Open/Short
G : General C : Crawler Type W : Wheel Type
侍#
Some error codes are not applied to this machine.
(SERIAL NO. : -#0610)
Summary of Contents for HX140L
Page 12: ...SECTION 1 GENERAL SECTION 1 GENERAL Group 1 Safety Hints 1 1 Group 2 Specifications 1 10...
Page 209: ...4 5 MEMORANDUM...
Page 694: ...8 68 125LCR8TM30 Turn casing 1 upside down and remove oil seal 3 using jig 29...
Page 734: ...8 108 Assemble plug 2 Plug NPT1 16 11 EA 17 21078TM68 21078TM69 21078TM70 21078TM71...
Page 756: ...8 130 Remove lock nut 22 and then boot 23 14 36078RL14 2507ARL10...