5-44
J1939 Code
Description
Effect and Action
3216-12
Aftertreatment #1 Intake NOx :
Failure
The data received from the NOx sensor is out of range.
The code is logged.
The warning lamp is illuminated.
Sensor (Data Link Type) - Test
3217-16
Aftertreatment #1 Intake O2 : High -
moderate Severity (2)
The Engine Out NOx Sensor is reading a higher than
expected level of Oxygen (02).
Clean Emissions Module Has High Oxygen Level
3226-5
Aftertreatment #1 Outlet NOx :
Current Below Normal
The ECM detects current that is below the acceptable
value.
Electrical Power Supply -Test
3226-6
Aftertreatment #1 Outlet NOx :
Current Above Normal
The ECM detects current that is above the acceptable
value
Electrical Power Supply -Test
3226-7
Aftertreatment #1 Outlet NOx : Not
Responding Properly
The engine out NOx level is not responding as expected.
The code is logged.
NOx Sensor - Test
3226-11
Aftertreatment #1 Outlet NOx : Other
Failure Mode
The NOx sensor cannot reach the correct operating
temperature in the defi ned time period.
Sensor (Data Link Type) - Test
3226-12
Aftertreatment #1 Outlet NOx :
Failure
The data received from the NOx sensor is out of range.
The code is logged.
The warning lamp is illuminated.
Sensor (Data Link Type) - Test
3227-16
Aftertreatment #1 Outlet O2 : High -
Moderate Severity (2)
The Engine Out NOx Sensor is reading a higher than
expected level of Oxygen (02).
Clean Emissions Module Has High Oxygen Level
3242-3
Particulate Trap Intake Gas
Temperature : Voltage Above Normal
The ECM detects the following conditions:
The signal voltage from the DPF inlet temperature sensor
is greater than 4.95 VDC for more than 8 seconds.
An active diagnostic code will be generated after 8
seconds. The diagnostic code will be logged if the engine
has been operating for more than 7 minutes “Voltage Above
Normal" will be displayed next to the status for “DPF Inlet
Temperature" on the electronic service tool.
Engine Temperature Sensor Open or Short Circuit - Test
(Active Sensors)
3242-4
Particulate Trap Intake Gas
Temperature : Voltage Below Normal
The ECM detects the following conditions:
The signal voltage from the DPF inlet temperature sensor
is less than 0.2 VDC for more than 8 seconds.
An active diagnostic code will be generated after 8
seconds. The diagnostic code will be logged if the engine
has been operating for more than 7 minutes “Voltage Below
Normal" will be displayed next to the status for “DPF Inlet
Temperature" on the electronic service too|.
Engine Temperature Sensor Open or Short Circuit - Test
(Active Sensors)
侍#
Some fault codes are not applied to this machine.
Summary of Contents for HX140L
Page 12: ...SECTION 1 GENERAL SECTION 1 GENERAL Group 1 Safety Hints 1 1 Group 2 Specifications 1 10...
Page 209: ...4 5 MEMORANDUM...
Page 694: ...8 68 125LCR8TM30 Turn casing 1 upside down and remove oil seal 3 using jig 29...
Page 734: ...8 108 Assemble plug 2 Plug NPT1 16 11 EA 17 21078TM68 21078TM69 21078TM70 21078TM71...
Page 756: ...8 130 Remove lock nut 22 and then boot 23 14 36078RL14 2507ARL10...