6-65
Wiring diagram
SPEC
Starting switch ON :
24
佳
1V
Starting switch OFF :
0V
See TEST 18
SPEC: 15-35
凂
See TEST 19
Is voltage between
CN-88(2)-GND
normal?
Check resistance
between CN-51
(18)-GND
Check resistance
between CN-88
(1)-(2)
Short circuit or poor
connection between
CN-88(1)-CN-52 (2)
Defective power
max. solenoid valve
Check hydraulic
system
Short circuit or poor
connection between
CN-51(18)-CS-29
Short circuit or poor
connection between
CN-88(2)-
Fuse No. 30
Repair or replace
Repair or replace
Repair or replace
Repair or replace
14. MALFUNCTION OF POWER MAX (SERIAL NO. : -#0610)
Fault code : HCESPN 166, FMI 4 or 6
Before carrying out below procedure, check all the related connectors are properly inserted.
INSPECTION PROCEDURE
侍
1)
MCU
CS-29
2
CN-52
18
CN-51
CN-88
5
CN-4
NO.30
2
1
6
2
1
POWER MAX SOLENOID
FUSE
POWER MAX SWITCH
Cause
Remedy
YES
YES
NO
NO
140L6MS03
SPEC : Power max button pressed ON : 0
凂
Power max button released OFF :
佹
凂
余
YES
NO