5-42
J1939 Code
Description
Effect and Action
1761-17
Aftertreatment #1 DEF/AdBlue® Tank
Volume : Low - least severe (1)
The level fl uid in the Diesel Exhaust Fluid (DEF) tank is
less than 14%.
The Emissions System Malfunction lamp comes on.
The code is logged.
DEF/AdBlue® Tank Level Is Low
1761-18
Aftertreatment #1 DEF/AdBlue® Tank
Volume : Low - moderate severity (2)
The level fl uid in the DEF tank is less than 8%.
The Emissions System Malfunction lamp is on and the
Action lamp fl ashes.
The code is logged.
The engine is derated.
DEF/AdBlue® Tank Level Is Low
2659-7
Engine Exhaust Gas Recirculation
(EGR) Mass Flow Rate : Not
Responding Properly
Actual mass fl ow through the NOx Reduction System (NRS)
does not match the desired mass fl ow.
The Electronic Control Module (ECM) has been powered
for at least 2 seconds.
The engine is running.
There are no active codes for the 5 VDC supply.
There are no active 27, 157, 411, 1188, 2791, 3358 or
3563 codes.
412-3 or 412-4 codes are not active.
NRS Mass Flow Rate Problem
2659-15
Engine Exhaust Gas Recirculation
(EGR) Mass Flow Rate : High - least
severe (1)
TBA
2791-3
Engine Exhaust Gas Recirculation
(EGR) Valve Control : Voltage Above
Normal
Motorized Valve - Test
2791-5
Engine Exhaust Gas Recirculation
(EGR) Valve Control : Current Below
Normal
The ECM detects the following conditions:
A low current condition in the output for the NOx Reduction
System (NRS) valve (EGR valve) for 2 seconds.
168 diagnostic codes are not active.
The ECM has been powered for at least 2 seconds.
If equipped, the warning lamp will come on. The ECM will
log the diagnostic code.
Motorized Valve - Test
2791-6
Engine Exhaust Gas Recirculation
(EGR) Valve Control : Current Above
Normal
The ECM detects the following conditions:
A high current condition in the output for the NRS valve
(EGR valve) for 2 seconds.
The ECM has been powered for at least 2 seconds.
If equipped, the warning lamp will come on. The ECM will
log the diagnostic code.
Motorized Valve - Test
2791-7
Engine Exhaust Gas Recirculation
(EGR) Valve Control : Not
Responding Properly
The ECM detects the following conditions:
The signal from the NRS valve position sensor indicates
that the valve is not in the desired position.
This diagnostic code can be caused by a loss of the 5 VDC
supply to the NRS valve position sensor.
The ECM has been powered for at least 2 seconds.
If equipped, the warning lamp will come on. The ECM will
log the diagnostic code.
Motorized Valve - Test
侍#
Some fault codes are not applied to this machine.
Summary of Contents for HX140L
Page 12: ...SECTION 1 GENERAL SECTION 1 GENERAL Group 1 Safety Hints 1 1 Group 2 Specifications 1 10...
Page 209: ...4 5 MEMORANDUM...
Page 694: ...8 68 125LCR8TM30 Turn casing 1 upside down and remove oil seal 3 using jig 29...
Page 734: ...8 108 Assemble plug 2 Plug NPT1 16 11 EA 17 21078TM68 21078TM69 21078TM70 21078TM71...
Page 756: ...8 130 Remove lock nut 22 and then boot 23 14 36078RL14 2507ARL10...