5-5
3. USER MODE SELECTION SYSTEM
High idle rpm, auto idle rpm and EPPR pressure can be adjusted and memorized in the U-mode.
LCD segment vs parameter setting
Step
( )
Engine speed
(rpm)
Idle speed
(rpm)
Power shift
(bar)
1
1300
750
0
2
1400
800
3
3
1500
850
6
4
1600
900
9
5
1700
950
12
6
1800
1000
16
7
1850
1050
20
8
1900
1100 (auto decel)
26
9
1950
1150
32
10
2000
1200
38
1)
2)
CAN #1 & #2
Main pump
Pilot pump
Engine
ECM
CAN #1
Main control valve
Pump power
shift EPPR
MCU
Drive signal
Cluster
User mode switch signal
User mode
pilot lamp
Normal
CN-16
Emergency
CN-16A
CN-16B
Haptic controller
CLUSTER
AIRCON
OFF
CAN #2
140L5MS104