6-24
GROUP 3 ELECTRICAL SYSTEM
1. WHEN STARTING SWITCH IS TURNED ON, MONITOR PANEL DISPLAY DOES NOT APPEAR
余
Before disconnecting the connector, always turn the starting switch OFF.
余
Before carrying out below procedure, check all the related connectors are properly inserted and
short of fuse No. 9, 15.
余
After checking, insert the disconnected connectors again immediately unless otherwise specified.
YES
YES
NO
NO
Check voltage
between
CN-56A (2)
and (3)
Check voltage
between CN-5
(9) and (10)
CLUSTER
BATT (24V)
GND
POWER IG (24V)
1
2
3
CN-56A
11
10
9
CN-5
NO.9
FUSE
NO.15
FUSE
Starting switch : ON
Voltage : 20~32V
Cause
Remedy
Defective cluster
Disconnection in
wiring harness or
poor contact
between
CN-5-CN-56A
Disconnection in
wiring harness or
poor contact
between CN-5 (9)
-GND or fuse No.
9, 15
Replace
Repair or replace
(after clean)
Repair or replace
(after clean)
140L6ES01
Starting switch : ON
Voltage : 20~32V
YES
NO
20~32V
0V
Check voltage
(SERIAL NO. : -#0610)
Summary of Contents for HX140L
Page 12: ...SECTION 1 GENERAL SECTION 1 GENERAL Group 1 Safety Hints 1 1 Group 2 Specifications 1 10...
Page 209: ...4 5 MEMORANDUM...
Page 694: ...8 68 125LCR8TM30 Turn casing 1 upside down and remove oil seal 3 using jig 29...
Page 734: ...8 108 Assemble plug 2 Plug NPT1 16 11 EA 17 21078TM68 21078TM69 21078TM70 21078TM71...
Page 756: ...8 130 Remove lock nut 22 and then boot 23 14 36078RL14 2507ARL10...