5-52-2
侍#
Some fault codes are not applied to this machine.
J1939 Code
Description
Effect and Action
5629-31
Particulate Trap Active Regeneration
Inhibited Due To Low Exhaust Gas
Pressure - least severe (1)
Diesel Particulate Filter Collects Excessive Soot
5706-5
Aftertreatment #1 Diesel Exhaust
Fluid Pump Heater : Current Below
Normal
This code indicates low current to the DEF pump motor.
The code is logged.
DEF/AdBlue® Pump - Test
5706-6
Aftertreatment #1 Diesel Exhaust
Fluid Pump Heater : Current Above
Normal
This code indicates low current to the DEF pump motor.
The code is logged.
DEF/AdBlue® Pump - Test
5758-11
Aftertreatment #1 Intake Gas Sensor
Power Supply : Other Failure Mode
The ECM detects voltage that is outside the acceptable
value.
Electrical Power Supply - Test
5759-11
Aftertreatment #1 Outlet Gas Sensor
Power Supply : Other Failure Mode
The ECM detects voltage that is outside the acceptable
value.
Electrical Power Supply - Test
5965-5
Aftertreatment #1 DEF/AdBlue®
Control Module Relay Control :
Current Below Normal
The Electronic Control Module (ECM) detects a low current
condition in the aftertreatment power relay circuit.
Relay - Test (Aftertreatment Power Relay)
5965-6
Aftertreatment #1 DEF/AdBlue®
Control Module Relay Control :
Current Above Normal
The ECM detects a high current condition in the
aftertreatment power relay circuit.
Relay - Test (Aftertreatment Power Relay)
5966-5
Aftertreatment #1 DEF/AdBlue®
Control Module Power Supply :
Current Below Normal
A low current condition has been detected on the start
switch circuit between the engine ECM and the DCU.
DEF/AdBlue® Control Module Power - Test
5966-6
Aftertreatment #1 DEF/AdBlue®
Control Module Power Supply :
Current Above Normal
A high current condition has been detected on the start
switch circuit between the engine ECM and the DCU.
DEF/AdBlue® Control Module Power - Test
6309-5
Aftertreatment #1 Diesel Exhaust
Fluid Control Module Power Supply 2
: Current Below Normal
A low current condition has been detected on the start
switch circuit between the engine ECM and the DCU.
DEF/AdBlue® Control Module Power - Test
6309-6
Aftertreatment #1 Diesel Exhaust
Fluid Control Module Power Supply 2
: Current Above Normal
A high current condition has been detected on the start
switch circuit between the engine ECM and the DCU.
DEF/AdBlue® Control Module Power - Test
7441-3
Aftertreatment Ambient Air
Temperature : Voltage Above Normal
The ECM detects the following conditions:
The signal voltage from the aftertreatment ambient air
temperature sensor is greater than 4.95 VDC for more than
8 seconds.
An active diagnostic code will be generated after 8 seconds.
The diagnostic code will be logged if the engine has been
operating for more than 7 minutes “Voltage Above Normal"
will be displayed next to the status for “'Aftertreatment
Ambient Air Temperature" on the electronic service tool.
Sensor Signal (Analog, Passive) - Test
Summary of Contents for HX140L
Page 12: ...SECTION 1 GENERAL SECTION 1 GENERAL Group 1 Safety Hints 1 1 Group 2 Specifications 1 10...
Page 209: ...4 5 MEMORANDUM...
Page 694: ...8 68 125LCR8TM30 Turn casing 1 upside down and remove oil seal 3 using jig 29...
Page 734: ...8 108 Assemble plug 2 Plug NPT1 16 11 EA 17 21078TM68 21078TM69 21078TM70 21078TM71...
Page 756: ...8 130 Remove lock nut 22 and then boot 23 14 36078RL14 2507ARL10...