2-44
Opening of the poppet causes the pressure in chamber A to fall and the plunger to open. As the
result the pressurized oil at port P runs into tank passage (T).
(3)
The pressure at port P becomes lower than set pressure of the spring, the poppet is seated by
spring force. Then the pressure at port P becomes equal to set pressure of the spring and the
plunger is seated to the socket.
(4)
P
Housing
Tank
passage
T
Tank passage
T
Chamber A
Poppet
Plunger
14W92MC43
P
Socket
Housing
Tank
passage
T
Poppet
Spring
Plunger
14W92MC44