![Hyundai HX140L Manual Download Page 562](http://html.mh-extra.com/html/hyundai/hx140l/hx140l_manual_2196330562.webp)
7-14
Unit : kgf
CONTROL LEVER OPERATING FORCE
Use a spring scale to measure the
maximum resistance of each control lever
at the middle of the grip.
Preparation
Keep the hydraulic oil temperature at
50
·
5˚C.
Measurement
Start the engine.
Select the following switch positions.
Power mode switch: P mode
Operate each boom, arm, bucket and
swing lever at full stroke and measure the
maximum operating force for each.
Lower the bucket to the ground to raise
one track off the ground. Operate the
travel lever at full stroke and measure the
maximum operating force required.
When finished, lower the track and then
jack-up the other track.
Repeat steps
ྛ
and
ྜ
three times and
calculate the average values.
Evaluation
11)
(1)
(2)
ྙ
(3)
ྙ
ྚ
½
ྛ
ྜ
ྜྷ
The measured operating force should be within the following specifications.
Model
HX140 L
Kind of lever
Boom lever
Arm lever
Bucket lever
Swing lever
Travel lever
Standard
1.3 or below
1.3 or below
1.3 or below
1.3 or below
2.1 or below
Maximum allowable
1.7
1.7
1.7
1.7
3.15
Remarks
(4)
Summary of Contents for HX140L
Page 12: ...SECTION 1 GENERAL SECTION 1 GENERAL Group 1 Safety Hints 1 1 Group 2 Specifications 1 10...
Page 209: ...4 5 MEMORANDUM...
Page 694: ...8 68 125LCR8TM30 Turn casing 1 upside down and remove oil seal 3 using jig 29...
Page 734: ...8 108 Assemble plug 2 Plug NPT1 16 11 EA 17 21078TM68 21078TM69 21078TM70 21078TM71...
Page 756: ...8 130 Remove lock nut 22 and then boot 23 14 36078RL14 2507ARL10...