5-32
J1939 Code
Description
Effect and Action
412-15
Engine Exhaust Gas Recirculation
Temperature : High - least severe (1)
Engines equipped with a Diesel Particulate Filter (DPF):
The exhaust gas temperature in the NRS has reached
178
佾
(352
俈
) for 8 seconds.
Engines not equipped with a DPF : The exhaust gas
temperature in the NRS has reached 198
佾
(388
俈
) for 8
seconds.
The ECM has been powered for at least 2 seconds.
The engine has been running for at least 180 seconds.
There are no electrical faults on the circuit.
NRS Exhaust Gas Temperature Is High
412-16
Engine Exhaust Gas Recirculation
Temperature : High - moderate
severity (2)
Engines equipped with a DPF : The exhaust gas
temperature in the NRS has reached 180
佾
(356
俈
) for 8
seconds.
Engines not equipped with a DPF : The exhaust gas
temperature in the NRS has reached 190
佾
(374
俈
) for 8
seconds.
The engine will be derated.
The ECM has been powered for at least 2 seconds.
The engine has been running for at least 180 seconds.
There are no electrical faults on the circuit.
NRS Exhaust Gas Temperature Is High
558-2
Accelerator Pedal 1 Low Idle Switch :
Erratic, Intermittent or Incorrect
The EIectronic Control Module (ECM) detects the following
condition:
The signal from the Idle Validation Switch (IVS) is invalid.
If equipped, the warning light will come on. The ECM will
log the diagnostic code.
Idle Validation Switch Circuit - Test
626-5
Engine Start Enable Device 1 :
Current Below Normal
The Electronic Control Module (ECM) detects a low current
condition in the output from the ECM to the solenoid for
ether injection.
The code is latched. The code is logged.
Ether injection is disabled
Ether Starting Aid - Test
626-6
Engine Start Enable Device 1 :
Current Above Normal
The ECM detects a high current condition in the output
from the ECM to the solenoid for ether injection.
The code is latched. The code is logged.
Ether injection is disabled.
Ether Starting Aid - Test
630-2
Calibration Memory : Erratic,
Intermittent or Incorrect
The engine Electronic Control Module (ECM) detects that
one or more of the programmable parameters have not
been programmed.
The ECM may use a default torque map or the ECM may
limit the engine to low idle.
The code is active only.
Flash Programming
631-2
Calibration Module : Erratic,
Intermittent or Incorrect
ECM Memory - Test
侍#
Some fault codes are not applied to this machine.
Summary of Contents for HX140L
Page 12: ...SECTION 1 GENERAL SECTION 1 GENERAL Group 1 Safety Hints 1 1 Group 2 Specifications 1 10...
Page 209: ...4 5 MEMORANDUM...
Page 694: ...8 68 125LCR8TM30 Turn casing 1 upside down and remove oil seal 3 using jig 29...
Page 734: ...8 108 Assemble plug 2 Plug NPT1 16 11 EA 17 21078TM68 21078TM69 21078TM70 21078TM71...
Page 756: ...8 130 Remove lock nut 22 and then boot 23 14 36078RL14 2507ARL10...