5-9
GROUP 6 AUTOMATIC WARMING UP SYSTEM
CAN #2
Main pump
Pilot pump
Engine
ECM
CAN #1
Main control valve
Pump power
shift EPPR
MCU
Drive signal
Cluster
Warming up pilot lamp signal
Warming up
pilot lamp
Hydraulic temp sensor
Normal
CN-16
Emergency
CN-16A
CN-16B
Haptic controller
CLUSTER
AIRCON
OFF
CAN #1 & #2
The MCU receives the engine coolant temperature from the ECM, and if the coolant temperature is
below 30
˚
C, it increases the engine speed from key start rpm to 1100 rpm. At this time the mode
does not change. If the coolant temperature sensor has fault, the hydraulic oil temperature signal is
substituted.
In case of the coolant temperature increases up to 30
˚
C, the engine speed is decreased to key start
speed. And if an operator changes power mode set during the warming up function, the MCU
cancels the automatic warming up function.
LOGIC TABLE
1.
2.
3.
140L5MS08
Description
Condition
Function
Actuated
- Coolant temperature :
below 30˚C (after engine run)
- Power mode : Default (E mode)
- Warming up time : 10 minutes (max)
- Warming up pilot lamp : ON
Canceled
- Coolant temperature : Above 30˚C
- Warming up time : Above 10 minutes
- Changed power mode set by operator
- RCV lever or pedal operating
- Auto idle cancel
侍#
If any of the above conditions is
applicable, the automatic warming up
function is canceled
- Power mode : set mode
- Warming up pilot lamp : OFF
Summary of Contents for HX140L
Page 12: ...SECTION 1 GENERAL SECTION 1 GENERAL Group 1 Safety Hints 1 1 Group 2 Specifications 1 10...
Page 209: ...4 5 MEMORANDUM...
Page 694: ...8 68 125LCR8TM30 Turn casing 1 upside down and remove oil seal 3 using jig 29...
Page 734: ...8 108 Assemble plug 2 Plug NPT1 16 11 EA 17 21078TM68 21078TM69 21078TM70 21078TM71...
Page 756: ...8 130 Remove lock nut 22 and then boot 23 14 36078RL14 2507ARL10...