![Hyundai HX140L Manual Download Page 372](http://html.mh-extra.com/html/hyundai/hx140l/hx140l_manual_2196330372.webp)
5-45
J1939 Code
Description
Effect and Action
3242-17
Particulate Trap Intake Gas
Temperature : Low - least severe (1)
The temperature at the intake of the DPF is below the
trip point that is calculated by the ECM. The trip point
varies depending on engine operating conditions.
The code is logged. The code remains active until electrical
power to the ECM is cycled.
Diesel Particulate Filter Temperature Is High
3242-18
Particulate Trap Intake Gas
Temperature : Low - moderate
severity (2)
The temperature sensor is not correctly installed.
Engine power is derated 30%. The code is logged. The
code remains active until electrical power to the ECM is
cycled.
Diesel Particulate Filter Temperature Is Low
3358-3
Engine Exhaust Gas Recirculation
Inlet Pressure :
Voltage Above Normal
The ECM detects signal voltage that is not in the
acceptable range.
The code is logged.
The value of the parameter is set to a gauge pressure.
Engine Pressure Sensor Open or Short Circuit - Test
3358-4
Engine Exhaust Gas Recirculation
Inlet Pressure : Voltage Below Normal
The ECM detects signal voltage that is not in the
acceptable range.
The code is logged.
The value of the parameter is set to a gauge pressure.
Engine Pressure Sensor Open or Short Circuit - Test
3358-13
Engine Exhaust Gas Recirculation
Inlet Pressure : Calibration Required
The ECM detects the following conditions:
The offset between the NRS inlet pressure and the
barometric pressure is outside the acceptable range during
initialization check.
The offset between the NRS inlet pressure and the
barometric pressure is outside the acceptable range during
sensor calibration when the engine is not running.
The warning lamp will come on and the engine will derate.
The code is logged.
Sensor Calibration Required - Test
3358-21
Engine Exhaust Gas Recirculation
Inlet Pressure : Data Drifted Low
5 V Sensor Supply Circuit - Test
3360-3
Aftertreatment #1 DEF/AdBlue®
Controller : Voltage Above Normal
The ECM detects current that is above the acceptable
value.
Electrical Power Supply -Test
3360-4
Aftertreatment #1 DEF/AdBlue®
Controller : Voltage Below Normal
The ECM detects current that is below the acceptable
value
Electrical Power Supply -Test
3360-9
Aftertreatment #1 DEF/AdBlue®
Controller : Abnormal Update Rate
The Dosing Control Unit (DCU) has incorrectly stopped or
started transmitting a data request.
This diagnostic code applies to the CAN A datalink.
The ECM will log the diagnostic code.
Can Data Link - Test
3360-14
Aftertreatment #1 DEF/AdBlue®
Controller : Special Instruction
The data received from the OCU is not in the correct
format.
The warning lamp is illuminated.
Sensor (Data Link Type) - Test
侍#
Some fault codes are not applied to this machine.
Summary of Contents for HX140L
Page 12: ...SECTION 1 GENERAL SECTION 1 GENERAL Group 1 Safety Hints 1 1 Group 2 Specifications 1 10...
Page 209: ...4 5 MEMORANDUM...
Page 694: ...8 68 125LCR8TM30 Turn casing 1 upside down and remove oil seal 3 using jig 29...
Page 734: ...8 108 Assemble plug 2 Plug NPT1 16 11 EA 17 21078TM68 21078TM69 21078TM70 21078TM71...
Page 756: ...8 130 Remove lock nut 22 and then boot 23 14 36078RL14 2507ARL10...