2.1 Instrument Labels and Functions
25
2
Chapte
r 2 Instrument La
bels and
Screens
Rear Panel
Used for input of the power supply to operate the
instrument.
Used to connect the power cord provided.
Marked with a black dot (
) in the power line voltage
specification section.
Used for input of the power supply for equipment
under test.
Used to connect the power cord provided.
(Maximum rating: 250 V/20 A)
Correct measurements are not made when no
voltage is input to [LINE IN].
See
Input/output terminal for external control.
(The proper connector is required for connection.)
See
Used to connect an RS-232C cable or 9444 Con-
nection Cable (for the 9442 Printer).
(The 9442 Printer, 9444 Connection Cable,
and other accessories are optional products.)
See
Used to connect a USB cable.
(The USB terminal provides communication func-
tions but no storage capacity.)
See
1. Power inlet [AC IN]
2. Power source rating
3. Inlet for power line of equipment under test
[LINE IN]
4. EXT I/O connector
5. RS-232C connector
6. USB connector
Terminal for connecting function ground terminal
and power supply system for measurement. Con-
nect to E (earth) for [LINE IN].
Enables connection to earth during leakage current
measurements. (only ST5540)
See
Terminal for connecting patient connection to
ground for power supply circuit for measurement.
Connect to E (earth) for [LINE IN].
Enables connection to earth during leakage current
measurements. (only ST5540)
See
Terminal providing ground connection for metal
accessible part not protectively earthed. Connect to
E (earth) for [LINE IN]. Enables ground connection
during leakage current measurements. (only
ST5540)
See
Connected to E (earth) of [LINE IN].
This is a permanent connection that cannot be
changed.
*
Setting enabled only when B1 or B2 network
is selected.
7. S10 terminal*
8. S12 terminal*
9. S13 terminal*
10. E terminal
1
2
3
4
5
6
78910
Summary of Contents for ST5540
Page 2: ......
Page 6: ...Contents iv Index i ...
Page 29: ...23 2 Chapter 2 Instrument Labels and Screens Instrument Labels and Screens Chapter 2 ...
Page 80: ...4 8 Changing the Measurement Method Auto Manual 74 ...
Page 121: ...115 8 9 7 Chapter 7 Instrument System Settings Instrument System Settings Chapter 7 ...
Page 144: ...7 14 Setting the Backlight 138 ...
Page 284: ...10 14 Measurement Networks 278 ...
Page 290: ...11 4 Instrument Disposal 284 ...
Page 320: ...Appendix4 External Dimensions A30 ...
Page 323: ......
Page 324: ......
Page 325: ......
Page 326: ......