8.7 Command Message Description
240
Example
Command
:SYSTem:TEST:RELay:STARt ON
Performs relay check at power on.
Query
Response
:SYSTem:TEST:RELay:STARt?
:SYSTEM:TEST:RELAY:START ON
(Headers: ON)
ON
(Headers: OFF)
Performs relay check at power on.
Sets and queries the relay check (At power on)
Queries the VA check
Syntax
Query
Response
:SYSTem:TEST:VA?
<numerical value 1>,<numerical value 2>,<numerical value 3>,<numerical
value 4>,<numerical value 5>,<numerical value 6>
<numerical value 1>
= Voltage value(between L and N)(NR3)
<numerical value 2>
= Current value(NR3)
<numerical value 3>
= VA value(NR3)
<numerical value 4>
= Voltage value(between L and G)(NR3)
<numerical value 5>
= Voltage value(between N and G)(NR3)
<numerical value 6>
= Judgement(NR1)
See the table below.
Function
Query
Conducts the VA check and returns the results.
Example
Query
Response
:SYSTem:TEST:VA?
:SYSTEM:TEST:VA +100.0E+00,+12.00E+00,
+1.200E+03,+100.0E+00,+0.000E+00,0
(Headers : ON)
+100.0E+00,+12.00E+00,+1.200E+03,+100.0E+00,+0.0
00E+00,0
(Headers : OFF)
The results of the VA check are as follows :
<Voltage value>
: 100.0 V(between L and N)
<Current value>
: 12.0 A
<VA value>
: 1200 VA
<Voltage value>
: 100.0 V(between L and G)
<Voltage value>
: 0.0 V(between N and G)
<Judgement>
: No error
Error
An execution error occurs in the following cases :
• When the measurement mode is selected
• When a mode other than "leakage current mode" is set
Note
• Use this command after executing the : MODE command to activate OFF
mode (i.e., measurement mode not selected).
• When data displayed by the instrument is "less than 0.5A," the largest value
that is less than the numeric value of the data is returned.
• When the voltage is less than 80.0 V, +9.999E+09 is returned as the VA
value, voltage (between L and G), and voltage (between N and G).
128
64
32
16
8
4
2
1
bit 7
bit 6
bit 5
bit 4
bit 3
bit 2
bit 1
bit 0
Not used
Not used
Not used
Reverse
polarity
Grounding
error
VA error
Current
error
Voltage
error
Summary of Contents for ST5540
Page 2: ......
Page 6: ...Contents iv Index i ...
Page 29: ...23 2 Chapter 2 Instrument Labels and Screens Instrument Labels and Screens Chapter 2 ...
Page 80: ...4 8 Changing the Measurement Method Auto Manual 74 ...
Page 121: ...115 8 9 7 Chapter 7 Instrument System Settings Instrument System Settings Chapter 7 ...
Page 144: ...7 14 Setting the Backlight 138 ...
Page 284: ...10 14 Measurement Networks 278 ...
Page 290: ...11 4 Instrument Disposal 284 ...
Page 320: ...Appendix4 External Dimensions A30 ...
Page 323: ......
Page 324: ......
Page 325: ......
Page 326: ......