Official GSK Agents in South Africa
Tel: +27 11 626 2720, [email protected]
GSK218MC Series Machining Center CNC System PLC&Installation Connetion Manual
114
V
o
lume
III Function
End signal of the 4
th
reference position return
ZP41---ZP45 (F044#0---#4)
[Type]
Signal output
[Function]
This signal shows that the machine tool has been held in the reference
position of the controllable axis.
These signals are one-to-one corresponding with the axes.
Table 4-2-2
ZP*1
End signal of the 1
st
axis reference position return
ZP*2
End signal of the 2
nd
axis reference position return
ZP*3
End signal of the 3
rd
axis reference position return
ZP*4
End signal of the 4
th
axis reference position return
ZP*5
End signal of the 5
th
axis reference position return
[Condition output]
This signal is enabled when the detection allowance signal (G57, G58 and G59) of the
reference position is set to 1. The signal becomes 1 when the following states are
displayed.
z
The manual reference position return has been completed, and its current
position is located on the in-position area.
z
The automatic reference position return (G30) has been completed, and its
current position is located on the in-position area
z
The detection of the reference position return has been completed, and its
current position is located on the in-position area.
The signal becomes 0 when the following states are displayed:
z
The detection permission signal (G57, G58 and G59) of the reference
position is set to 0
z
The machine tool moves from the reference position.
z
The ESP signal occurs
z
The servo alarm generates.
4.3 Area Detection Signal
Area detection signal
AQ1—AQ3 (F045#0---#2)
[Type]
Signal output
[Function]
This signal shows that the machine tool has been held in the area range of the