n
3.2 Timer
Press the
[TMR]
soft key in the
Fig. 3-1
, then enter the checking and setting interfaces of the
timer, refer to the
Fig. 3-2-1
.
Fig. 3-2-1
The content and operation of the timer:
RUN :
Operation state of ladder diagram.
N0. :
Timer serial number; Do no change it.
ADDR. :
Timer address; Do not change it.
CURT :
Current value of the timer; Do not change it.
SET :
Presetting value of the timer; it can be changed after the K000.0 (PLC parameter
allows to be modified) is set 1 in the MDI mode.
Input :
Input data display
MDI mode :
Current working mode
[Return] :
Return to the previous menu
[
X
] :
Enter to the next page.
The set value can be downloaded to the CNC operation pressing the <
Save
> key after
modifying. “TMR downloading successful” displays after the save is performed; the system displays:
“downloading fail” when the save is incorrect; the “illegal downloading parameter” displays without
downloading conditions.
The search and positioning can be performed by the page-up, page-down and four direction
keys on the panel; checking and modifying of the timer address can be performed.