Official GSK Agents in South Africa
Tel: +27 11 626 2720, [email protected]
GSK218MC Series Machining Center CNC System PLC&Installation Connetion Manual
308
Appendix
Add.
Description
Presetting value
D015
No.15 tool case number
15 (The installed tool number inside the tool
case)
D016
No.16 tool case number
16 (The installed tool number inside the tool
case)
D017
No.17 tool case number
17 (The installed tool number inside the tool
case)
D018
No.18 tool case number
18 (The installed tool number inside the tool
case)
D019
No.19 tool case number
19 (The installed tool number inside the tool
case)
D020
No.20 tool case number
20 (The installed tool number inside the tool
case)
D021
No.21 tool case number
21 (The installed tool number inside the tool
case)
D022
No.22 tool case number
22 (The installed tool number inside the tool
case)
D023
No.23 tool case number
23 (The installed tool number inside the tool
case)
D024
No.24 tool case number
24 (The installed tool number inside the tool
case)
D100
Tool magazine capacity
24
D241
T code tool number
Fail to set
D243
Current tool magazine
tool case number
Fail to set
D245
Spindle tool number
Precautions:
1. The setting value of the D100 should be less than 100, and it is identical with the setting value
of the CTR100; otherwise, the abnormality may occur.
For example:
When D100=16, the data table D001-D016 are enabled.
When D100=24, the data table D001-D024 are enabled.
2. D000 is only displayed the tool number of the spindle, instead of altering the tool number at
the D000; it is better to modify at the 245 when spindle tool number modification is required.
3. Do not modify the value of the D241.
4. D240
~
D247 are used by system, and user can not self-defined.
5. Refer to the Section III for details.
Table 7 The definition of the CTR parameter
Add.
Presetting
value
Current value
Function explanation