Chapter Four Machine Debugging
229
V
o
lume IV
Inst
allation &
Connecti
on
State
add.
Y1.2
Y1.1
Pin
No.
XS43.9 XS43.21
Y1.1= Chip-removal switch control, Y1.2=Lubrication switch control.
z
The
internal
circuit
is
shown in the Fig. 4-13-1:
4.14 Setting Related to Feedrate
System parameter number
0 1 2
RDR FDR TDR RFO
LRP RPD
RPD
=1: The manual rapid is enabled from the switch-on to the before of
reference position return.
=0: The manual rapid is disabled from the switch-on to the before of
reference position return.
LRP
=1: Positioning (G00) interpolation type is linear.
=0: Positioning (G00) interpolation type is non-linear.
RFO
=1: Rapid feed, It stops when its feedrate is F0.
=0: Rapid feed, It holds when its feedrate is F0.
TDR
=1: The dry run is enabled during tapping.
=0: The dry run is disabled during tapping.
FDR
=1: The dry run is enabled during cutting feed.
=0: The dry run is disabled during cutting feed.
RDR
=1: The dry run is enabled during rapid positioning.
=0: The dry run is disabled during rapid positioning.
0086
Dry run velocity
5000
Setting range: 0
~
9999 (mm/min)
0087
Cutting feedrate when the power is turned on
300