Official GSK Agents in South Africa
Tel: +27 11 626 2720, [email protected]
GSK218MC Series Machining Center CNC System PLC&Installation Connetion Manual
118
V
o
lume
III Function
Signal address
5.2 Resetting
Brief
: The CNC is reset and entered into the reset state in the following conditions:
1. The ESP signal is set to 1.
2. Press the <RESET> key on MDI
The reset signal RST outputs to PLC when CNC is reset. After the above-mentioned
conditions are released, the reset signal RST is set to 0 when it outputs the time set by
parameter No.203.
RST
=
T
reset
(Resetting treatment time) + the setting value of the parameter No.203
Fig. 5-2
In the automatic operation, the automatic operation stops when CNC is reset, and the
operation axis decelerates then stops.
The CNC is reset during performing the M, S, T function, the MF, SF and TF signals are
set to 0 within 16ms.
RST
(
F001
#
1
)
[Type]
Signal output
[Function]
PLC and CNC is already reset, this signal is used for treating the PLC
reset.
[Condition output]
This signal is set to 1 based upon the following conditions:
1. ESP signal is set to 1.
2. Press the <RESET> key on MDI.
This signal is set to 0 in the following case:
After the abovementioned conditions are released, and then the CNC is reset. The reset signal
output time set by parameter No.203 has been ended.
SP
ST
G023
#
7
#
6
#
5
#
4
#
3
#
2
#
1
#
0
OP
STL
SPL
F000