Official GSK Agents in South Africa
Tel: +27 11 626 2720, [email protected]
Appendix I Ladder Diagram Usage Guide of GSK218mc Series with Cone Type Tool-Magazine
251
Appendix
Add.
Definition
State 0
State 1
K010.2
Whether the tool-magazine zero return switch is selected
the NC type
NORM type
NC type
K010.3
Whether the tool-magazine infeed switch is selected the
NC type
NORM type
NC type
K010.4
Whether the tool-magazine retraction switch is selected the
NC type
NORM type
NC type
K010.5
Whether the tool-magazine counting switch is selected the
NC type
NORM type
NC type
K010.6 Whether the tool-magazine origin set by hand is enabled
Disabled
Enabled
K010.7 Whether
the
tool-magazine enters adjustment mode
No
Yes
K011.1 Manual return tool-change position permission
Prohibition
Permission
K011.2 Whether the tool-magazine forward in-position
Connection Disconnection
K011.5
Whether output the positive signal when spindle is
positioned
No Yes
K012.0 Whether the spindle inspection with cutter is enabled
No
Yes
K012.1 Whether the spindle cutter inspection switch is NC type
No
Yes
K012.2
Whether the current tool-magazine cutter head inspection
with cutter are enabled
No Yes
K012.3
Whether the current cutter head inspection switch is NC
type
No Yes
K014.0
Whether use the index worktable clamping/releasing
equipment
No Yes
K014.1
Whether the worktable index is automatic
releasing/clamping
No Yes
K014.2
Whether the worktable releasing/clamping is without
inspection switch
With Without
K014.3 Index worktable prohibits manual MPG single block
No
Yes
K014.4
Whether the index table releasing state permits moving X Y
Z axes
No Yes
K014.5
Whether cut off the output after the index worktable release
the clamping
No Yes
K014.7 Index worktable enters the debugging mode
No
Yes
Precautions:
1. When the system is normally operated, it is necessary to confirm the states of K000.0,
K000.1, K000.2, K000.3, K000.4, K000.5, K000.6, K000.7, K005.2 and K010.7 are 0;
otherwise, the unexpected accident may happen.
2. The system can be enabled after its power is turned again until the parameter K001.0 is
altered. K010.1, K010.2, K010.3, K010.4, K010.5, K010.6, K010.7, K011.1 and K011.2
are disenabled when K001.0=0 (That is, regardless of using the tool-magazine)
3. The K008.2 is disabled when K001.0=1 (That is, tool-magazine is enabled).