simultaneously, the state parameter
No: 19#0 ~ No: 19#4
are set to 1. It is necessary to further judge
the malfunction is on the side of the system or the drive unit when the system displays the drive unit
alarm.
System parameter number
0 1 9
ALMS
ALM5
ALM4
ALM3
ALM2 ALM1
ALM1
=1: It alarms when the 1
st
axis drive alarm signal is set to1.
=0: It alarms when the 1
st
axis drive alarm signal is set to0.
ALM2
=1: It alarms when the 2
nd
axis drive alarm signal is set to1.
=0: It alarms when the 2
nd
axis drive alarm signal is set to0.
ALM3
=1: It alarms when the 3
rd
axis drive alarm signal is set to1.
=0: It alarms when the 3
rd
axis drive alarm signal is set to 0.
ALM4
=1: It alarms when the 4
th
axis drive alarm signal is set to1.
=0: It alarms when the 4
th
axis drive alarm signal is set to 0.
ALM5
=1: It alarms when the 5
th
axis drive alarm signal is set to1.
=0: It alarms when the 5
th
axis drive alarm signal is set to 0.
ALMS
=1: It alarms when the spindle drive alarm signal is set to1.
=0: It alarms when the spindle drive alarm signal is set to 0.
System parameter number
0
6
1
FALM
SALM
SALM
=1: Regardless of the spindle drive unit alarm.
=0: Regard for the spindle drive unit alarm.
FALM
=1: Regardless of the feed axis drive unit alarm.
=0: Regard for the feed axis drive unit alarm.
4.7 Machine Tool Pitch Compensation
z
The precautions set by the pitch error compensation
1. The set compensation amount is related with the position relationships between the zero and
compensation point, the mechanical movement direction and compensation interval, etc.
2. The compensation amount of the compensation point N (N=0, 1, 2, 3, ……255) is determined
by mechanical error of the area N, N-1. The compensation point number along with each axis
can be set to 256.
3. The mechanical zero is regarded as the compensation origin, and the compensation data set
by each axis is set as the parameter value.