Official GSK Agents in South Africa
Tel: +27 11 626 2720, [email protected]
Appendix II Laddar Diagram Use Guide of GSK218mc Series Matching with Disc Tool Magazine
295
Appendix
Troubleshooting:
Alarm information: 1223 Spindle velocity detection abnormality (A002.7)
Fault reason: User self-defined
Troubleshooting:
Alarm information: 1224 Spindle motor enabling detection abnormality (A003.0)
Fault reason: User self-defined
Troubleshooting:
Alarm information: 1225 Spindle orientation in-position detection abnormality (A003.1)
Fault reason: When the spindle performs the positioning motion (that is: Y2.1=1), the spindle
positioning detection switch (X7.1) is still connected within the setting time of the
T013.
Troubleshooting: 1. Spindle drive unit or spindle encoder abnormality.
2. Check whether the Y6.3 is output.
3. Readjust the time of the T013.
Alarm information: 1226 Spindle gear abnormality (A003.2)
Fault reason: Check the spindle gear abnormality
Troubleshooting: The gear I in-position detection switch (X004.1) does not close within the setting
time of the T0021 when the spindle changes the gear I (that is: Y3.4=1), adjust the
time of the T0021 or check whether the X004.1 is closed. The gear I in-position
detection switch (X004.2) does not close within the setting time of the T0022
when the spindle changes the gear II (that is: Y3.5=1), adjust the time of the
T0022 or check whether the X004.2 is closed. The gear I in-position detection
switch (X004.3) does not close within the setting time of the T0023 when the
spindle changes the gear I (that is: Y3.6=1), adjust the time of the T0023 or check
whether the X004.3 is closed.
Alarm information: 1227 Do not to perform the cycle start because the manipulator does not at the
origin position (A003.3)
Fault reason: If the manipulator does not at the origin position, press the “Start” button in the Auto,
MDI or DNC mode, the alarm will occur.
Troubleshooting: Performing the manipulator returns to the origin.