Official GSK Agents in South Africa
Tel: +27 11 626 2720, [email protected]
Appendix I Ladder Diagram Usage Guide of GSK218mc Series with Cone Type Tool-Magazine
275
Appendix
a. In the manual mode, press the
or
, so that the tool magazine No.1 tool case
rotates to the tool-change position.
b. In the MDI mode, set the K010.6 to 1.
c. In the mechanical zero return mode, press then
till to the “Tool magazine zero return
indicator” ON.
d. Set the K010.6 to 0.
3. The adjust of the spindle positioning angle and tool-change coordinate position
A. The adjust of the spindle positioning angle (Refer to the User Manual for the Spindle Drive
Unit)
The adjust steps of the spindle positioning angle (Examples):
1) Input the system debugging password. Press the
, then enter the “Set (Password)”
interface by [Password] soft-key. In the MDI mode, input the system debugging password, and then
press the
. The “password correct” shows at the left corner.
2) Press the
key on MDI keyboard, press [KPAR] software in the [ PLCPAR] interface,
and then enter the viewing and setting interface of the non-volatile relay. Position the cursor to the
K010.7 (Whether the tool magazine enters the adjust mode) by the four direction buttons on the
keyboard; press the number “1”, then
, and then the
, the data column prompts:
“KPAR download successful!”, it means the storage is executed, and the tool magazine adjust mode
is then enabled (The tool magazine can perform the forward or backward freely). In this case, the
system alarm: 1253 Carefully operate the tool magazine adjust mode, cancel this alarm by
resetting button.
3) Prepare a tool handle, disassemble the nail.
4) Perform the Z axis zero return operation in the zero return mode.
5) In the system manual mode, press
, so that the tool magazine is performed at the
forward position.