PMC
alarm No.
A add.
Alarm Content
release
1273
A009.1
Fail to operate the manipulator because the spindle tool does not
clamp
1274
A009.2
Do not perform the tool-pivoting because the manipulator does not at
the origin
1275
A009.3
Do not perform the tool-retraction because the manipulator does not at
the origin
1276
A009.4
Do not rotate the cutter-head because the manipulator does not at the
origin
1277
A009.5
Do not rotate the cutter-head because the tool case does not put on
the horizontal place
1278 A009.6 The
manipulator
can not be operated because the Z axis does not
return to the 2
nd
reference position.
1279 A009.7
Manipulator
origin detection abnormality
1280
A010.0
Enforce to stop the rotation because the tool magazine rotation
abnormality
1288
A011.0
Index worktable releasing/clamping detection overtime
1289
A011.1
Index worktable clamping/releasing detection abnormality
1290
A011.2
Fail to use the index worktable clamping equipment
1291
A011.3
Fail to rotate because the index worktable does not release
1292
A011.4
Fail to move because the index worktable does not clamp
1293
A011.5
Do not cycle start because the safety door opens
1294
A011.6
Do not shift in the rigid tapping, it is necessary to cancel the rigid
tapping and then shift.
1360
A020.0
Low lubrication pressure grease level
The alarms between A0.0~A19.7 are the red interruption alarms of the system; the system
stops after alarm. A20.0~A31.7 are the yellow prompt alarms for the user self-defined; the system
continues after alarm without affecting the normal use.
The details of PMC section alarm diagnosis information:
Alarm information: 1200 Air pressure detection abnormality (A000.0)
Fault reason:
Troubleshooting: Detect the state of the X002.0
Alarm information: 1201 Lubrication detection abnormality (A000.1)
Fault reason: User self-defined
Troubleshooting: