GSK218MC Series Machining Center CNC System PLC & Installation Connection Manual
40
Volume I
Programming
Fig. 5-16-2
Parameter:
Length1: Specify the byte number of the binary system data of the conversion data in the
conversion table.
1: Binary system of 1 byte.
2: Binary system of 2 bytes.
Up to 512 bytes.
Length2: The capacity of the conversion table data. Each conversion table capacity can
not more than 100, it is 100 bytes when 1 type format is specified; it is 100 bits
when 2 bytes format are specified. The total capacity of the entire COD codes
conversion table should be less than 512 bytes.
S1: The data in the conversion table can be taken out by the specifying table number,
and the address of the specifying table number is regarded as the input address of
the conversion data. This address should be supplied a register with one byte.
S2: The output address of the conversion data. Specify the byte numbers of the register
in the form specification beginning with the address.
Output:
If the abnormal occurs during the COD code performs. W=1, it indicates that the error issues.
Note:
The capacity of the conversion data table is up to 100 bytes (bits), this table is compiled between the
parameter conversion data output address and error output (W).
5.17 COM (Concentric Line Control)
Function
COM specifies the control until the coil working within the public end code COME range. The
system may alarm if the public end code does not specified.
Format: