Official GSK Agents in South Africa
Tel: +27 11 626 2720, [email protected]
Chapter Six Feedrate Control
125
V
o
lume
III Function
specified feedrate in the program is 100mm/min, the override is set to 50%, the machine is
then moves at the speed of 50mm/min.
Signal Code detection signal of feedrate override (G011#3~G011#7)
[Type]
Signal input
[Function]
There are 5 binary system code signals are corresponding to the override for
the cutting feedrate override signal:
So, the override can be selected based upon the unit of the 10% within the range of the
0~200%.
Note: The feedrate both 218MC-H and 218MC-V are controlled by the feed brand switch.
6.3 Override Cancellation
Brief
The feedrate override is fixed on 100% by the override cancellation signal.
Signal Override cancellation signal
OVC
(
G024
#
1
)
[Type] Signal input
[Function] The feedrate override is fixed on 100%.
[Motion] The CNC operation is shown below when the signal is set to 1:
z
The feedrate override is fixed on 100% regardless of the feedrate override
signal.
z
No affection in the rapid traverse override and spindle speed override.
Signal address
OVC
G024
#
7
#
6
#
5
#
4
#
3
#
2
#
1
#
0