Appendix I Ladder Diagram Usage Guide of GSK218mc Series with Cone Type Tool-Magazine
267
Appendix
The alarm of the “User self-defined” in the fault reason does not design in the ladder diagram,
user should add it by altering the ladder diagram.
Table 5 The definition of the TMR parameter
Add. Note
Initial
value (ms)
User setting
value (ms)
T001
Spindle positive completion delayer
500
T002
Spindle negative completion delayer
500
T003
Spindle shift completion delay time
500
T004 Spindle
positioning
completion delayer
0
T005
Miscellaneous function completion delayer
0
T006 Spindle
shift
delayer
500
T007
Spindle tool releasing completion delayer
500
T008
Spindle tool clamping completion delayer
500
T009
Spindle tool releasing in-position detection time
8000
T010
Spindle tool clamping in-position detection time
8000
T011
Pulse signal 1 time for 1 second
50
T012
Pulse signal 2 time for 1 second
50
T013
Spindle positioning detection time setting
8000
T014
Spindle positive detection time setting
500
T015
Spindle negative detection time setting
500
T016
Lubrication OFF time setting (Unit: minute)
30
T017
Lubrication ON time setting (Unit: second)
10
T018
Spindle positioning delay detection time setting
2000
T019
Spindle JOG delayer
500
T020
Program restart delayer
10
T021
Spindle gear I delay detector
10000
T022
Spindle gear II delay detector
10000
T023
Spindle gear III delay detector
10000
T024
Spindle velocity position mode conversion detection
time
10000
T025
M29 execution completion time (It is enabled without
detection signal)
4000
T026
The positioning completion time in the spindle
position mode (It is enabled without the detection
signal)
2000
T027
M28 execution completion time (It is enabled without
detection signal)
2000
T028
Spindle position velocity mode conversion detection
time
10000
T029
Spindle brake time
1000
T030
The shift delay time when the spindle gear 1 is
without the detection switch
3000