Official GSK Agents in South Africa
Tel: +27 11 626 2720, [email protected]
Appendix I Ladder Diagram Usage Guide of GSK218mc Series with Cone Type Tool-Magazine
269
Appendix
D098
The No.98 tool number
D099
The No.99 tool number
D100
Tool magazine capacity
D241
T code tool number
Fail to set
D243
Current tool case number
Fail to set
D245
Spindle tool number
Precautions:
1. The setting value of the D100 should be less than 100, which should be same with the one
of the CTR100; otherwise the abnormality may occur.
For example:
When D100=16, D001-D016 in the data table are enabled.
When D100=24, D001-D024 in the data table are enabled.
2. D000 only displays the spindle tool number, and the spindle tool number can not be
modified in the D000, it is better to alter it at theD245 when the spindle tool number should
be altered.
3. The value of the D241 can not be modified.
4. D240
~
D247 are used by system, so user can not self-defined.
5. Refer to the Section three for details.
Table 7 The definition of the CTR parameter
Add.
Note
Initial value
User setting value
C100
Tool magazine capacity setting
16
Precaution:
1. The setting value of the CTR 100 should be less than 100, which should be same with the
one of the D100; otherwise the abnormality may occur.
For example: CTR100=16, the tool case number of the tool magazine is 16.
CTR100=24, the tool case number of the tool magazine is 24.
Table 8 The definition of the M code
M code
F signal
Function
Remark
M00 F031.7
Program
stop
M01 F030.4
Selection
stop
M02 F030.5
Program
end
M03 F030.0
Spindle
positive
M04 F030.1
Spindle
negative
M05 F030.2
Spindle
stop
M06 F030.3
Automatic
tool-change
M08 F031.0
Coolant
ON
M09 F031.1
Coolant
OFF