Official GSK Agents in South Africa
Tel: +27 11 626 2720, [email protected]
GSK218MC Series Machining Center CNC System PLC&Installation Connetion Manual
312
Appendix
2. The setting value of the DATA100 and CTR100 should be less than 100.
For example:
The DATA100 and CRT100 are set to 24 when tool magazine capacity is 24.
E. The setting of the tool number in the tool magazine:
D001--D099 in the data table are separately corresponding to the tool case No. 1 to 99 in the
tool magazine. The setting values in the data table D001--D099 are separately corresponding to the
tool number of the No. 1 to 99 tool case in the tool magazine. D245 is the tool number on the
spindle.
Precautions:
1. Fail to set the same tool number (other than the 0) in the D001--D099; otherwise, the alarm
occurs when tool-change.
2. The setting range of the tool number should be suitable for the setting requirement of the
data parameter 0206; otherwise, the alarm may occur when performing the T code.
For example:
If the tool magazine capacity is 24 and the D1-D24 will be set as 1—24 in turn;
the No. 8 tool case will perform the tool change after rotating to the tool-change position when
executing the T8M6. If it is set to 10, 20, 30… 240 in the D1—D24 in turn, the No. 8 tool case will
perform the tool change after rotating to the tool-change position when executing the T80M6. If both
the D1 and D2 are set to 8, the alarm may occur when performing the T8M6.
F. The setting of the time parameter (TMR) related with the tool magazine
Add. Note
Setting
range
Initial
value (ms)
T004
Spindle positioning completion delayer
More than or equal to 0
0
T007
Spindle tool releasing completion delayer
More than or equal to 0
0
T008
Spindle tool clamping completion delayer
More than or equal to 0
0
T009 Spindle tool releasing detection time setting
More than the tool
releasing time
8000
T010 Spindle tool clamping detection time setting
More than the tool clamping
time
8000
T013
Spindle positioning detection time setting
More than the positioning
time
8000
T018 Spindle
positioning
delay detection time
setting
It is related with the
positioning width
2000
T036 Index worktable releasing completion delay
More than or equal to 0
500
T037 Index worktable clamping completion delay
More than or equal to 0
500
T038
Index worktable releasing delay detection
More than or equal to 0
5000
T039
Index worktable clamping delay detection
More than or equal to 0
5000
T040 Index worktable releasing delay completion
More than or equal to 0
4000
T041 Index worktable clamping delay completion
More than or equal to 0
4000