GSK218MC Series Machining Center CNC System PLC&Installation Connetion Manual
254
Appendix
PLC
alarm No.
Add. A
Alarm content
1255
A006.7
Fail to return to the origin position for the tool clamping
1256
A007.0
Fail to return to the tool-change position for the tool clamping
1257
A007.1
Fail to return to the tool-change position for the spindle absence
positioning
1258
A007.2
Fail to return to the tool-change position for the tool magazine
abnormality
1260
A007.4
Do not cycle start the manual return tool-change position state
1261
A007.5
Fail to retract due to out of the origin
1262
A007.6
Exceed the safety position
1264
A008.0
Abnormal spindle velocity position mode conversion
1265
A008.1
Abnormal spindle position velocity mode conversion
1267
A008.3
Abnormal tool magazine forward/backward detection
1268
A008.4
Abnormal spindle releasing/clamping detection
1269
A008.5
Abnormal spindle orientation time-sequence detection
1270
A008.6
Do not perform the tool-change when Z axis is not returned to the
mechanical zero
1271
A008.7
Enforce to stop the rotation when the tool magazine abnormality
1272
A009.0
Spindle tool number detection abnormality
1273
A009.1
Fail to forward when current cutter head and tool number are with the
cutters
1274
A009.2
Fail to forward the tool magazine due to the cutter head does not
perform the in-position
1288
A011.0
Index worktable releasing/clamping detection is overtime
1289
A011.1
Abnormal index worktable releasing/releasing detection
1290
A011.2
Fail to use the index worktable clamping equipment
1291
A011.3
Fail to rotate the index worktable due to it is clamping
1292
A011.4
Fail to move the index worktable due to it is releasing
1293
A011.5
Do not cycle start the safety door due to it is open
1294
A011.6
Do not change the gear during rigid tapping, it is better firstly cancel
the rigid tapping and then change the gear.
1360
A020.0
Low lubrication pressure or grease level
The alarms between the A0.0~A19.7 are the red interruption alarm for the system. The system
stops after alarms. A20.0~A31.7 are the self-defined yellow prompt alarm by the user; the system
continues to operate after the alarm occurs. Normally, the system can be operated as usual.
The details of PLC alarm diagnosis information:
Alarm information: 1200 Abnormal air pressure detection (A000.0)
Fault reason:
Troubleshooting: Detect the state of the X002.0