Pin No.
XS42.15
XS42.02 XS42.14
X4.1= the spindle gear
I
in-position
;
X4.2= the spindle gear
II
in-position
;
X4.3= the spindle gear
III
in-position.
z
Control
parameter
State parameter
0
0
1
SPT
SPT
=1: The spindle control type: I/O point control.
=0: The spindle control type: frequency-conversion or other modes.
Data parameters No.246
2 4 6
The top rotation velocity corresponding the gear 1
The spindle rotation velocity when the frequency transformer is corresponding to the 10V at the
spindle gear 1.
Data parameters No.247
2 4 7
The top rotation velocity corresponding the gear 1
The spindle rotation velocity when the frequency transformer is corresponding to the 10V at the
spindle gear 2.
Data parameters No.248
2 4 8
The top rotation velocity corresponding the gear 1
The spindle rotation velocity when the frequency transformer is corresponding to the 10V at the
spindle gear 3.
Data parameters No.250
2 5 0
Motor velocity when shifting the spindle gear
The velocity related to the data parameter 251
Data parameters No.251
2 5 1
The top rotation velocity of the motor when shifting the spindle gear
The motor’s velocity when the frequency transformer is corresponding to the 10V voltage.
Note:
1. K8.4 sets to 1 when the automatic shifting equipment is installed in the machine; otherwise, it sets to 0. The Max.
rotation velocity of the gear 1 is regarded as default and guarantee 246
≥
247
≥
248 when the automatic gear-shift
function is disabled.
2. K9.3 sets to 1, otherwise, 0 when there is no detection switch on the spindle gear inspection.