Appendix II Laddar Diagram Use Guide of GSK218mc Series Matching with Disc Tool Magazine
297
Appendix
the abnormality is eliminated.
Alarm information: 1235 Tool magazine movement in-position detection abnormality (A004.3)
Fault reason: User self-defined
Troubleshooting:
Alarm information: 1236 Tool magazine zero return detection abnormality (A004.4)
Fault reason: User self-defined
Troubleshooting:
Alarm information: 1237 Zero return gain because the tool magazine zero position is absent
(A004.5)
Fault reason: The zero return abnormality stops so that the alarm occurs when the tool magazine
performs the zero return.
Troubleshooting: Tool magazine returns to the zero again.
(Refer to the details operation: Section Three The Usage and Maintenance of the GSK218MC
Series with Disk Tool-magazine)
Alarm information: 1238 Tool case horizontal/vertical detection abnormality (A004.6)
Fault reason: The tool case neither at the horizontal position nor at the vertical one.
Troubleshooting: Check whether the detection signal of X51 and X5.2 are normal.
Alarm information: 1239 Fail to rotate the spindle because the tool case does not at the horizontal
position (A004.7)
Fault reason: Perform the spindle rotation when the tool case does not at the horizontal position.
Troubleshooting: Return the tool case to the horizontal position (Detecting the tool case returns to
the horizontal position by inspecting the state of the X5.2), and then perform the
spindle rotation.
Alarm information: 1240 Zero return again because the tool magazine abnormality (A005.0)
Fault reason: 1. The tool magazine counting switch (X5.3) abnormality is detected so that the pulse
signal occurs after the tool magazine stops the setting time of rotating the T102.
2. When the tool magazine rotates, the tool magazine counting switch 0 or 1 is
detected, which exceeds the setting time of the T103.
Troubleshooting: 1. The output section (Y3.0 and Y3.1) of the tool magazine’s positive or negative
are abnormal