Appendix II Laddar Diagram Use Guide of GSK218mc Series Matching with Disc Tool Magazine
287
Appendix
Add.
Definition
State 0
State 1
User
setting
value
K008.7
Whether the spindle mode conversion is without
detection signal
With Without
K009.0
Whether the spindle position arrival is without
detection switch
With Without
K009.1
Whether the lubrication pressure or grease level
detection is enabled
Not
detection
Detection
K009.2
Whether the air source pressure detection is enabled
Not
detection
Detection
K009.3
Whether the spindle gear detection is without
detection switch
With Without
K010.1
Whether the tool magazine is with zero return switch
Without
With
K010.2
Whether the tool magazine zero return switch is
selected the NC type
NORM NC
K010.3
Whether the tool magazine infeed switch is selected
the NC type
NORM NC
K010.4
Whether the tool magazine retraction switch is
selected the NC type
NORM NC
K010.5
Whether the tool magazine counting switch is
selected the NC type
NORM NC
K010.6
Whether the tool magazine origin set by manual is
enabled
Disabled Enabled
K010.7
Whether the tool magazine enters the adjustment
mode
No Yes
K011.5
Whether output the positive signal when spindle
positioning
No Yes
K012.0
Whether the manipulator brake signal is selected the
NC type
NORM NC
K012.1
Whether the manipulator tool-hold signal is selected
the NC type
NORM NC
K012.2
Whether the manipulator zero return signal is
selected the NC type
NORM NC
K012.3
Whether the current cutter head detection switch is
NC type
No Yes
K012.7 Whether
the
manipulator enters the adjustment mode
No
Yes
K014.0
Whether use the index worktable clamping/releasing
equipment
No Yes
K014.1
Whether the worktable index is automatic
clamping/releasing
No Yes
K014.2
Whether the worktable clamping/releasing is without
detection switch
With Without
K014.3
Index worktable prohibits the manual MPG single
block
Permission Prohibition