Official GSK Agents in South Africa
Tel: +27 11 626 2720, [email protected]
GSK218MC Series Machining Center CNC System PLC&Installation Connetion Manual
232
V
o
lume IV
Inst
allation
&
Connecti
o
n
=0:The gear ratio of the spindle and the position encoder can not be
random.
DOV
=1: The override is enabled during the rapid tapping retraction.
=0: The override is disabled during the rapid tapping retraction.
PCP
=1: The tapping is high velocity deep peck tapping cycle.
=0: The tapping is standard deep peck tapping cycle.
System parameter number
0
4
5
OVS
OVU
TDR
NIZ
NIZ
=1: Perform the smooth processing for rigid tapping
=0: Do not perform the smooth processing for rigid tapping
TDR
=1: Use the identical time constant when the rigid tapping performs
infeed/retraction.
=0: Do not use the identical time constant when the rigid tapping performs
infeed/retraction.
OVU
=1: Rigid tapping retraction override 10%
=0: Rigid tapping retraction override 1%
OVS
=1: The feedrate override selection and override cancellation signal in the
rigid tapping are enabled.
=0: The feedrate override selection and override cancellation signal in the
rigid tapping are disabled.
System parameter number
0
4
6
ORI
SSOG
SSOG
=1: The spindle control mode is servo when the tapping starts.
=0: The spindle control mode is follow when the tapping starts.
ORI
=1: The spindle performs the exact stop when tapping starts.
=0: The spindle does not perform the exact stop when tapping starts.
K parameter number
0
0
7
PAP
DGN
=1: Use the spindle position mode.
=0: Do not use the spindle position mode.
It is set to 1 when using the rigid tapping, and set to 0 when using the
flexible tapping.