Appendix I Ladder Diagram Usage Guide of GSK218mc Series with Cone Type Tool-Magazine
249
Appendix
Add. Single
interface
Interface
pin
Definition
Y003.0 XS44
8
Tool-magazine positive
Y003.1 XS44
21
Tool-magazine
negative
Y003.2 XS44
9
Tool-magazine
forward
Y003.3 XS44
22
Tool-magazine
backward
Y003.4
XS44
24
Spindle gear I (Frequency conversion /IO point control)
Y003.5
XS44
12
Spindle gear II (Frequency conversion /IO point control)
Y003.6
XS44
25
Spindle gear III (Frequency conversion /IO point control)
Y003.7 XS44
13
Undefined
Y004.0 XS45
1
Undefined
Y004.1 XS45
14
Undefined
Y004.2 XS45
2
Undefined
Y004.3 XS45
15
Undefined
Y004.4 XS45
17
Undefined
Y004.5 XS45
5
Undefined
Y004.6 XS45
18
Undefined
Y004.7 XS45
6
Undefined
Y005.0 XS45
8
Undefined
Y005.1 XS45
21
Undefined
Y005.2 XS45
9
Undefined
Y005.3 XS45
22
Undefined
Y005.4 XS45
24
Undefined
Y005.5 XS45
12
Undefined
Y005.6 XS45
25
Undefined
Y005.7 XS45
13
Undefined
Y006.0 XS23
9
Spindle
positive
Y006.1 XS23
25
Spindle
negative
Y006.2 XS23
24
Spindle
enabling
Y006.3 XS23
11
Spindle
orientation
Y006.4 XS23
12
Spindle
velocity/position shifting
Y006.5 XS23
27
Zero
clamping
Precautions:
1. Refer to the Chapter Four for the connection and caution of the PLC input part (Y).
2. User can add a new function (The ladder diagram should be modified when using the
undefined part, it is better to carefully operate) to the undefined input part by modifying the
ladder diagram when using this ladder diagram.
Table 3 KPAR address definition
Add.
Definition
State 0
State 1
K000.0 PLC parameter modification permission
Prohibition
Permission