Official GSK Agents in South Africa
Tel: +27 11 626 2720, [email protected]
GSK218MC Series Machining Center CNC System PLC&Installation Connetion Manual
124
V
o
lume
III Function
CHAPTER SIX FEEDRATE CONTROL
6.1 Rapid Traverse Rate
Brief
4-gear override (F0, 25
%
, 50
%
and 100
%
) can be used for the rapid traverse rate.
Fig. 6-1
Feedrate:
The actual move speed is gained from which the setting value of the parameter
P088~092 multiples the override value, regardless in the Auto or manual
operation (it consists of the manual reference position return and program zero
return).
F0 speed It is determined by parameter P093.
Signal The code signal of the rapid traverse rate (G11#0~G11#1)
[Type] Signal input
[Function] It is the code detection signal of the rapid traverse override.
[Motion] The code signal corresponding with the following override
Code signal at the rapid traverse rate
RV1 RV2
Override value
1 1
100%
0 1
50%
1 0
25%
0 0
F0
*The velocity of the F0 can be set by parameter (Data parameter P93).
6.2 Feedrate Override
Brief
The override disk can be selected to increase or decrease the programming feedrate by the
percentage. This character is used for the programming detection. For example, when the