Cisco Catalyst Switch Manager Alarms
Chassis
The following table describes the Chassis object state alarms.
Power Supply
The following table describes the Power Supply objects state alarms.
Table 13-4 Chassis State Alarms
State
Description
Severity
Alarms Cleared
discovery
“C6576M Chassis is in the discovery
state. Chassis and subchassis discovery
is being performed.”
Informational
normal
performance
discoverylostcomms
“C6576M Chassis is in the
discoverylostcomms state. Network
connectivity to switch has been lost
during discovery.”
normal
“C6576M Chassis is in the normal
state.”
Normal
discovery
performance
normallostcomms
“C6576M Chassis is in the normal
state.”
Normal
performance
performance
“C6576M Chassis is in the performance
state.”
Informational
discovery
normal
perflostcomms
“C6576M Chassis is in the lostcomms
state. Network connectivity to switch
has been lost.”
Informational
discovery
normal
Table 13-5 Power Supply State Alarms
State
Description
Severity
Alarms Cleared
normal
“C6576M Power Supply is in the normal
state.”
Informational lostcomms
lostcomms
“C6576M Power Supply is in the lostcomms
state. Network connectivity to the power
supply has been lost.”
Critical
normal